header-page

Resources

Registration Forms, Manuals, and Policies

Referrals

Customers who have peace of mind with an American Alarm Systems security system often share their experiences with their family, friends and colleagues.  We think it is only fair that if you support us, we support you in return.  With our referral program, if you refer us to someone who then becomes a client of American Alarm Systems, Inc., you will receive 3 months free monitoring on your monitored account.

To qualify, ALL of the following requirements must be met:

  • All person(s) you refer must sign up for 24-hour monitoring.
  • You must submit your referral information online by completing the attached form.
  • Only new referrals qualify for the 3 months free monitoring (not to exceed $150).
  • Referral rewards are not retroactive.
  • Referring must be a residential or business customer with an AAS security system installed, active and in good standing.

*No cash value.  Offer subject to change.

Referral form

Alarm Permits

You may need to obtain a valid alarm permit if you have a monitored security alarm system.  There is usually an annual cost, $25 – $40, associated with maintaining a valid alarm permit.  Each county and city has different requirements.  Contact your county or city for their requirements.

In cities that require alarm permits, there are often increased penalties and fees for false alarms for homeowners who have not obtained an alarm permit.  It is very important to know what your county’s or city’s alarm permit requirements are to avoid the unnecessary cost of fees associated with not having an alarm permit when required.

Equipment Manuals

Whether you’re simply replacing a battery, or reprogramming your device, we have the manuals your need to make it happen!

Go!Control

Panel 2GIG Go!Control
Arm From Security Screen, press, “ARM”, “STAY” or “AWAY”.
Disarm To disarm when in STAY mode. From Security Screen, press “SECURITY”, “DISARM”, Enter code. To disarm when in AWAY mode,
Enter code.
Check Faulted Zones Press “STATUS”
Bypass Zones Press “ARM”, “BYPASS ALL”
Smoke Detector Silence/Reset Enter code.
Chime Mode On/Off Press “SECURITY”, “MENU”, “CHIME”
Change Code Press “SECURITY”, “MENU”, “TOOLBOX”, “USER CODES”, “CHANGE USER CODES”. Select code to change.
User Manual Manual

DSC 9047, 9057

Panels DSC 9047, 9057
Arm Enter your Code OR press the “STAY” or “AWAY” button for 2 seconds.
Disarm Enter your Code.
Check Faulted Zones For the LCD Alpha Keypad press the [>] key to scroll through the open zones.
Bypass Zones Enter [*][1] + [>] until desired zone displays [*] [#].
Smoke Detector Silence/Reset Reset the alarm by pressing [*][7].
Chime Mode On/Off Hold “CHIME” for 2 seconds to toggle On/Off.
Change Code LED Keypad: [*] [5] + [Master Code] + [>] to display user numbers [01-16] + press [*] to select, then [New Code] to add or change a code. Press [#] to exit the menu.
User Manual DSC 9047 — DSC 9057

DSC 1616,1832,1864

Panels DSC 1616, 1832, 1864
Arm Enter your Code OR press the “STAY” or “AWAY” button for 2 seconds.
Disarm Enter your Code.
Check Faulted Zones Press the [>] key to scroll through the open zones.
Bypass Zones Enter [*][1] then scroll to the zone to be bypassed and press [*].[B] will appear indicating the zone is bypassed. Press [#]. Arm System.
Smoke Detector Silence/Reset After silencing panel with Code, Reset the alarm by pressing [*][4] or [*][7][2].
Chime Mode On/Off Hold down chime button for 2 seconds, or Enter [*] [6] + [Access Code]. Scroll to the [Door Chime] feature and press [*] to turn on or off.
Change Code Enter [*] [5] + [Master Code] + [User Number 01-64]. You may also scroll through the list and press [*] to select a user number. Enter new 4-digit code. Press [#] to exit the menu.
User Manual Manual

DSC 832, 864

Panels DSC 832, 864
Arm Enter your Code OR press the “STAY” or “AWAY” button for 2 seconds.
Disarm Enter your Code.
Check Faulted Zones Press the [>] key to scroll through the open zones.
Bypass Zones Enter [*][1] then scroll to the zone to be bypassed and press [*].[B] will appear indicating the zone is bypassed. Press [#]. Arm System.
Smoke Detector Silence/Reset Silence the alarm by entering your Code. Press [*][72] to reset.
Chime Mode On/Off Hold down chime button for 2 seconds, or Enter [*] [6] + [Access Code]. Scroll to the [Door Chime] feature and press [*] to turn on or off.
Change Code Enter [*] [5] + [Master Code] + [User Number 01-64]. You may also scroll through the list and press [*] to select a user number. Enter new 4-digit code. Press [#] to exit the menu.
User Manual DSC 832 — DSC 864

DSC 4010, 4020

Panels DSC MAXSYS 4010, 4020
Arm Enter your Code OR press the “STAY” or “AWAY” button for 2 seconds.
Disarm Enter your Code.
Check Faulted Zones Press the [>] key to scroll through the open zones.
Bypass Zones Enter [*][1] then scroll to the zone to be bypassed and press [*].[B] will appear indicating the zone is bypassed. Press [#]. Arm System.
Smoke Detector Silence/Reset Silence the alarm by entering your Code. Press [*][4] to reset or [Code #, Code #].
Chime Mode On/Off Hold down chime button for 2 seconds, or Enter [*] [6] + [Access Code]. Scroll to the [Door Chime] feature and press [*] to turn on or off.
Change Code Enter [*] [5] + [Master Code] + [User Number 001-128]. You may also scroll through the list and press [*] to select a user number. Press [0] to add a new 4-digit code + [New Code] or [1] to delete an existing code. Press [#] to exit the menu.
User Manual DSC 4010 — DSC 4020

DSC 1550, 2550, 3000

Panels DSC 1550, 2550, 3000
Arm Enter your Code OR [*][0] for Quick Arm. Must have green Ready light on.
Disarm Enter your Code.
Check Faulted Zones Zone light [1-8] will be red indicating open zones.
Bypass Zones Enter [*][1][Zone number(s) to be bypassed]. Enter zone number(s) as single digits (1-6). As each zone is bypassed, the zone light will come ON. If a zone is bypassed in error, press that zone number again and the zone light will go OFF indicating that the zone is not bypassed.
Press [#] to return to Ready.
Smoke Detector Silence/Reset Silence the alarm by entering your Code. Press [*][4] or [*][7] to reset.
Chime Mode On/Off Enter [*] [6] + [Master Code][6] to turn on or off.
Change Code Enter [*] [5] + [Master Code][code number][new 4 digit code] The [code number] is a single digit either 2, 3, 4, 5 or 6. Press [#] to return to Ready. If an access code already exists, it will be replaced by the new code.
User Manual DSC 1550 — DSC 2550DSC 3000

Ademco Vista 10, 20

Panels Ademco Vista 10, 20 Series
Arm Code + [2] Away (Arms All) Code + [3] Stay (Arms Perimeter only)
Disarm Code + [1] OFF
Check Faulted Zones Press [*] key. The keypad will scroll through all faulted zones.
Bypass Zones Code + [6] + Zone number(s). Most panels use 2-digit zone numbers. Large Vista 100 and Vista 128 panels use 3-digit zone numbers.
Quick Bypass Code + [6] Bypass + #. The panel will bypass zones that are open.
Smoke Detector Silence/Reset Smoke Detectors mostly reset automatically with these panels when alarm is silenced at the keypad. However, you may have to enter Code + [1] OFF again to reset the smokes.
Chime Mode On/Off Code + [9] Chime.
Change Code Code + [8] Code + User # + 4 new digits. Most panels require a 2-digit user number. A few panels have 1-digit user numbers. Try a 2-digit user number first. If that doesn’t work, use a 1-digit number. Panels with complex configurations may require alpha keypads to change codes and will ask questions to complete after the above process is done.
User Manual ADEMCO Vista 10 — ADEMCO Vista 20

Radionics 6112, 8112

Panels Radionics 6112, 8112
Arm Code Shortcuts:[COMMAND][1] Arms All[COMMAND][2] Arms Perimeter w/ no delay[COMMAND][3] Arms w/ delay[COMMAND][47] Silence
Disarm Enter code.
Check Faulted Zones Press any numeric key [0-9] and keypad will scroll through faulted zones.
Bypass Open Zones If using Code to arm, hold last digit until panel arms over open zones. If using Command 1,2 or 3, press [COMMAND] and hold down the digit 1,2 or 3 until panel arms over open zones.
Smoke Detector Silence/Reset After silencing panel with Code, press [COMMAND][4][7] to reset smokes.
* If smoke has not cleared, the alarm may resound. Clear the detectors of smoke and repeat the sequence to reset.
Chime Mode On/Off [COMMAND][6] turns on/off the “Watch Mode”.
Change Code Please call American Alarm Systems so we can walk you through this code change. Press COMMAND][5][5], Old Code; New Code; New code again. D8112A and D8112E panels, the command is [COMMAND][5].
Important Note If you use Command 55, the user code will be a 6-digit number and the first 2 digits must stay the same (they are the user #). If you use Command 5, the user code will be a 5-digit number and the first digit must stay the same (it is the user #).
User Manual RADIONICS 4112, 6112 — RADIONICS 8112

DMP XR-500

Panels DMP XR-500
Arm Hold down Keypad Button 3 for two seconds when leaving or hold down keypad button 3 for two seconds when staying at home.
Disarm Enter code.
Check Faulted Zones Press “CMD”, “MENU”, “YES”, Enter Code,“ZONE STATUS”.
Bypass Zones Leave zone open, press “CMD”, “ARM”, “CMD”, “ALL”, “YES”.
Smoke Detector Silence/Reset After silencing panel with Code, Hold down keypad button 2 for two seconds.
Chime Mode On/Off Hold down Keypad Button 5 for two seconds.
Change Code “CMD”, “USER CODES”, “CHG”, “USER NUMBER”, COMMAND”, “SELECT”, enter New Code, “COMMAND”.
User Manual Manual

Cancellation Policy

We’re Here to Help

We value you as a customer and we’re sorry you are thinking about leaving.  Tell us what is on your mind so we can help resolve any concerns.

Regardless of where you are in your term, if you wish to cancel your American Alarm services, you must provide a written Notice of Cancellation.  This Notice of Cancellation must include:

  • Date
  • Account Number
  • Written note expressing desire to cancel
  • Valid Signature

You may e-mail (cancels@amalarm.com), mail (PO Box 10520, Santa Ana, CA 92711) or fax (714-547-1762) your Notice of Cancellation.  To accept a cancellation email it must be from the email address associated with your account.

Extenuating Circumstance

At American Alarm Systems we understand that at times the unexpected happens.  We also understand that when the unexpected happens changes in your life occur.  Because of that, American Alarm Systems is proud to offer a cancellation policy that is sensitive to unfortunate circumstances.  If a death, bankruptcy, transition to an assisted living home, active military duty, or other extenuating circumstance is the reason for your decision to cancel, please call us at 1-800-262-5276 ext 708.  Please be aware, when you call, your special circumstance may require specific documentation.  Calling does not always result in being released from your agreement with American Alarm Systems.  Special considerations are handled on a case by case basis.